Backed by a rich industry experience, we are able to offer a wide range of Process Logger to our clients. There are various process parameters which are to be logged / recorded against time in various industries. These can be physical parameters, such as temperature, flow, pressure, humidity, level or electrical parameters, such as AC / DC voltages, currents, power parameters.


Flow Logger

REQUEST CALLBACK

Flow Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Memory32 K
No. of ChannelsDual Channel
Frequency50 Hz
Voltage220 V AC
BrandAjinkya Electronic
Power SourceElectric
PhaseSingle Phase
Current input75mA

The IM 1910 Series Flow Logger offered by us are micro controller based digital and highly versatile loggers. These Flow Logger can work with external flow sensors offering either electrical output like 4-20mA or 0-10 V or pulses and are used for measuring flow of different kinds of liquids, such as water, diesel & oils. We offer flow sensors of PD (Positive Displacement) type and Turbine type that can be used along with these flow meters. These sensors are available from sizes 1” to 4” (15NB to 100NB) and are ideal for free flowing liquids without any sediment.

Features:

  • The intrusive type of sensors and fit on pipe lines with end flanges
  • Material of construction can be aluminum, brass, MS, SS304 or SS316 with delrin rotors depending on suitability for the liquid
  • Flow loggers derive the flow rate as well as total flow values from the input signal and record them against time
  • They can be thus used as flow totalisers as well
  • With addition of set point, they can control the flow amount to be dispensed


Specifications:

  • Display: 7 segment LED display / Alphanumeric LCD display
  • Inputs: 4-20mA / Pulses / Unbalance Bridge / 0-10 mV / 100 mV
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text / Direct Centronics Printer
  • Options: Serial Printer / Alarm Relay / Retransmission 4-20mA
  • Alarm: High/ Low / Very High / Very Low
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated / Battery Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top
Yes! I am Interested

LED Display Systems

REQUEST CALLBACK

LED Display Systems
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Display FunctionAnimation
Text ColorFull Colour
Frequency60 Hz
Power SourceElectric
PhaseSingle Phase
Current input75mA
Accuracy+1%

In Industrial applications various parameters like temperature, pressure, flow, humidity or electrical parameters like voltage, current, frequency etc are to be displayed to be viewed from greater distances. These displays can accept multiple inputs so as to work as Jumbo Display Scanners.

Features of these displays are:
  • Sizes from 1” to 1 ft
  • Various inputs possible like RTD / Thermocouples / 4-20mA / Pulses / Voltages / Current / Humidity etc.
  • Wall mount / Top hanging displays
  • Suitable for Indoor as well as outdoor use
Yes! I am Interested

Pressure Logger

REQUEST CALLBACK

Pressure Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Memory2MB USB Flash
BrandAjinkya Electronic
Accuracy+1%
Number of Channel1 to 8
Power SourceElectric
PhaseSingle Phase

Our organization deals in offering IM2000 Pressure Logger that accepts input from various types of pressure sensors, load cells, torque sensors and strain gauges. These can be used as pressure logger or load logger or strain gauge logger, which give output signal either in 4-20mA form or resistive bridge form.

Options available:

  • Display: 7 segment LED display / Alphanumeric LCD display / Graphic LCD display
  • Sensor Inputs: 4-20 mA / load cell / Wheatstone bridge / load cell
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text
  • Options: SMS alarm / Centronics Printer interface / Grouping of channels
  • Log Interval: Minute. Seconds / Hours.Minutes
  • Alarm: High/ Low / Very High / Very Low / Common relay/ Two relays/ Individual Channel Relays
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top / Flameproof.
Yes! I am Interested

Level Logger

REQUEST CALLBACK

Level Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Type of Data LoggerDigital Data Logger
Memory64 K
No. of ChannelsMultichannel
DisplayLCD
Accuracy+1%
Frequency50 Hz
Ip RatingIP61
Power SourceElectric
PhaseSingle Phase

Our range of Level Logger can take signal from external level sensors and record these values in memory. There are various methods for recording the level and they can be using level sensor, pressure sensor or load cell. In level sensors there are different types like resistance sensor, Doppler effect Radar sensors, Ultrasonic sensors. Our level logger can accept inputs from either of these sensors and derive the level value based on sensor signal input.

Specifications:

  • Display: 7 segment LED display / Alphanumeric LCD display
  • Inputs: 4-20mA / Resistance / 0-10V / 0-100 mV / 0-20mA
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text
  • Options: Serial Printer / Alarm Relay / Retransmission 4-20mA
  • Alarm: High/ Low / Very High / Very Low
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top / Flameproof
Yes! I am Interested

Current Logger

REQUEST CALLBACK

Current Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
BrandAjinkya Electronic
Frequency50 Hz
Voltage230 V AC
Ip RatingIP64
Power SourceElectric
Current input75mA

We offer Current Logger. This is a process parameters which are to be logged / recorded against time in various industries. It has 3 channel current data logger.

Specifications:

  • Suitable for single or three–phase alternating currents
  • Low conversion time
  • High resolution and accuracy
  • No power supply required
  • USB and Ethernet interfaces
  • Run multiple units on a single PC
Yes! I am Interested

Power Logger

REQUEST CALLBACK

Power Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
No. of ChannelsMultichannel
Type of Data LoggerDigital Data Logger
DisplayLCD
Power SourceElectric
Current input65mA
IP RatingIP63
Power1.5 kW

Backed by a rich industry experience, we are able to offer a wide range of Power Logger to our clients. There are various process parameters which are to be logged / recorded against time in various industries. These can be physical parameters, such as temperature, flow, pressure, humidity, level or electrical parameters, such as AC / DC voltages, currents, power parameters.

Specifications:

  • Includes soft carrying case
  • 4 flexible current probes (15 A/150 A/3000 A)
  • Power Log software
  • Voltage leads and clips
  • Color localization set
  • PC interface cable
  • International ac adapter (115/230 V, 50/60 Hz)
  • Printed English manual
  • Multi-language manual CD
Yes! I am Interested

Voltage Logger

REQUEST CALLBACK

Voltage Logger
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Memory64K
BrandAjinkya Electronic
Frequency50 Hz
Voltage230 V AC
Number of Channel1 to 8
Power SourceElectric
PhaseSingle Phase

Besides from physical parameters; application also demands logging of voltages and currents. The IM2000 series Voltage Logger / Current Logger / Power Logger offered by us can accept DC shunt inputs, signals from convertors 4-20mA range or CT current inputs for higher AC currents or AC signals from PT. These Flow Logger can calculate values from the recorded channels to generate additional channel values.

Specifications:

  • Display: 7 segment LED display / Alphanumeric LCD display / Graphic LCD display
  • Inputs: DC voltage / 0-75mV DC Shunt input / AC Voltage / AC current from CT
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text etc.
  • Options: SMS alarm / Centronics Printer interface
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Shirish Shah (Partner)
Ajinkya Electronic Systems
F 2, Old M I D C, M I D C, Mahim
Satara - 415004, Maharashtra, India
Call Us: 
Call Response Rate: 75%
Share Us :



Home  |   Profile   |  Our Product Range  |  Site Map  |   Contact Us

© Ajinkya Electronic Systems. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Ajinkya Electronic Systems